Slot Sensor SC3,5-N0-BU

Slot Sensor, Housing: PBT, Output 2-wire, Voltage: DC, Connection flexible leads LiY, P67

Free shipping on Web orders over $100

$114.00
(Each excl GST)
On Request
Quantity Breaks
1+
5+
25+
$114.00
$114.00
$114.00
SKU: PF-106567 Manufacturer part number: 106567

Technical data of  SC3,5-N0-BU

General specifications
Switching function Normally closed (NC)
Output type NAMUR
Slot width 3.5 mm
Depth of immersion (lateral) 5 ... 7 typ. 6 mm
Output type 2-wire
Nominal ratings
Nominal voltage 8.2 V (Ri approx. 1 kΩ)
Operating voltage 5 ... 25 V
Switching frequency 0 ... 3000 Hz
Hysteresis 0.21 ... 0.4 mm
Suitable for 2:1 technology yes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detected ≥ 3 mA at nominal voltage
Measuring plate detected ≤ 1 mA at nominal voltage
Switching state indicator LED, yellow
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
MTTFd 4968 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
NAMUR EN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibility NE 21:2007
Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level Ga IECEx PTB 11.0091X
Equipment protection level Gb IECEx PTB 11.0091X
Equipment protection level Da IECEx PTB 11.0091X
Equipment protection level Mb IECEx PTB 11.0091X
ATEX approval
Equipment protection level Ga PTB 99 ATEX 2219 X
Equipment protection level Gb PTB 99 ATEX 2219 X
Equipment protection level Gc (ic) PF13CERT2895 X
Equipment protection level Da PTB 99 ATEX 2219 X
UL approval cULus Listed, General Purpose
Ordinary Location E87056
Hazardous Location E501628
Control drawing 116-0453
CSA approval cCSAus Listed, General Purpose
CCC approval
Hazardous Location 2020322315002306
NEPSI approval
NEPSI certificate GYJ16.1391X
Marine approval DNVGL TAA00001A5
Ambient conditions
Ambient temperature -25 ... 100 °C (-13 ... 212 °F)
Mechanical specifications
Connection type flexible leads LiY
Housing material PBT
Degree of protection IP67
Cable
Cable diameter 1.1 mm ± 0.1 mm
Bending radius > 10 x cable diameter
Core cross-section 0.14 mm2
Length 500 mm
General information
Use in the hazardous area see instruction manuals
 
SKU
PF-106567
We strive to provide you with the best information we can, considering the images are not to scale and do not represent detailed perspectives of the respected products. If you notice any errors or omissions in this information, please let us know using the contact us tab on this page.
*
*
*
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Product Files

Technical data of  SC3,5-N0-BU

General specifications
Switching function Normally closed (NC)
Output type NAMUR
Slot width 3.5 mm
Depth of immersion (lateral) 5 ... 7 typ. 6 mm
Output type 2-wire
Nominal ratings
Nominal voltage 8.2 V (Ri approx. 1 kΩ)
Operating voltage 5 ... 25 V
Switching frequency 0 ... 3000 Hz
Hysteresis 0.21 ... 0.4 mm
Suitable for 2:1 technology yes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detected ≥ 3 mA at nominal voltage
Measuring plate detected ≤ 1 mA at nominal voltage
Switching state indicator LED, yellow
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
MTTFd 4968 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
NAMUR EN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibility NE 21:2007
Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level Ga IECEx PTB 11.0091X
Equipment protection level Gb IECEx PTB 11.0091X
Equipment protection level Da IECEx PTB 11.0091X
Equipment protection level Mb IECEx PTB 11.0091X
ATEX approval
Equipment protection level Ga PTB 99 ATEX 2219 X
Equipment protection level Gb PTB 99 ATEX 2219 X
Equipment protection level Gc (ic) PF13CERT2895 X
Equipment protection level Da PTB 99 ATEX 2219 X
UL approval cULus Listed, General Purpose
Ordinary Location E87056
Hazardous Location E501628
Control drawing 116-0453
CSA approval cCSAus Listed, General Purpose
CCC approval
Hazardous Location 2020322315002306
NEPSI approval
NEPSI certificate GYJ16.1391X
Marine approval DNVGL TAA00001A5
Ambient conditions
Ambient temperature -25 ... 100 °C (-13 ... 212 °F)
Mechanical specifications
Connection type flexible leads LiY
Housing material PBT
Degree of protection IP67
Cable
Cable diameter 1.1 mm ± 0.1 mm
Bending radius > 10 x cable diameter
Core cross-section 0.14 mm2
Length 500 mm
General information
Use in the hazardous area see instruction manuals
 
SKU
PF-106567