You have no items in your shopping cart.

KN41L-Sil Nicr/Ni Kca 2X0.5 Din

KN41L-SIL NiCr/Ni KCA, Extension and compensating cable, single-paired version, temperature measurement 2x0.5 DIN

Free shipping on Web orders over $100

$12.10 (Per/m excl GST)
Global Stock
SKU: LAPP-0152030 Manufacturer part number: 0152030

Norm references / Approvals

  • Space-saving and flexible
  • For more detailed information, see appendix T8 and data sheets

Application range

  • Allows temperature measurement even in places where non-contact temperature measurement is not possible or reasonable
  • The thermocouple is used to measure temperature as a part of monitoring the manufacturing process, thus the sheath material should be selected with reference to the maximum ambient temperature at its junction.
  • Conductor materials (alloys): 
    Fe/CuNi (LX, JX)
    Conductor alloys are identical to thermocouple alloys
  • NiCr/Ni (K, KX, KCA)
    K and KX version - conductor alloys are identical to thermocouple alloys
    KCA version: compensating alloys (for KCA: Fe/CuNi), not identical to thermocouple alloys
  • PtRh/Pt (RCB, SCB)
    Compensating alloys (for RCB, SCB: Cu/CuNi) are not identical to thermocouple alloys

Norm references / Approvals

  • Colour identity code DIN 43710 Negative conductor and outer sheath:Fe/CuNi: blueNiCr/Ni: greenPtRh/Pt: whitePositive conductor: always redIEC 60 584 Positive conductor and outer sheath:Fe/CuNi: blackNiCr/Ni: greenPtRh/Pt: orangeNegative conductor: always white

Product Make-up

  • Design abbreviations:
    PVC: Polyvinylchloride
    SIL: Silicone rubber
    GL: Glass fibre
    FEP: Fluorinated ethylene propylene
    EGL: E-Glass fibre
    C: Copper braiding screen
    ST: Aluminium foil screen
    S: Steel wire braiding
  • Design, for example PVC-PVC-S-PVC:
    - PVC core insulation
    - PVC inner sheath
    - Steel wire braiding
    - PVC outer sheath
  • Examples shown (top to bottom):
    Fe/CuNi DIN 2 x 1.5 PVC
    NiCr/Ni IEC 2 x 1.5 GL-GL
    PtRh/Pt IEC 2 x 1.5 GL-GL-S
    NiCr/Ni DIN 2 x 1.5 SIL-GL
    NiCr/Ni DIN 2 x 1.5 PVC-PVC
    PtRh/Pt DIN 2 x 1.5 SIL-SIL
    Fe/CuNi IEC 2 x 1.5 SIL-SIL-S
    NiCr/Ni IEC 2 x 1.5 SIL
    PtRh/Pt IEC 2 x 1.5 SIL-GL-S
    Fe/CuNi IEC 2 x 0.22 PVC-PVC-C-PVC
    NiCr/Ni IEC 2 x 1.5 PVC-ST-PVC
    Fe/CuNi DIN 2 x 1.5 PVC-PVC-S-PVC

Temperature range

  • (referring to insulation and sheath material)
    PVC: -5°C to +80°C
    Silicone: -25°C to +180°C
    Glass fibre: -25°C to +200°C
    FEP: -100°C to +205°C
    E-Glass: -25°C to +400°C
 
SKU
LAPP-0152030
We strive to provide you with the best information we can, considering the images are not to scale and do not represent detailed perspectives of the respected products. If you notice any errors or omissions in this information, please let us know using the contact us tab on this page.
Products specifications
Attribute name Attribute value
Number of Conductors 2
Conductor Size 0.5mm
*
*
*
Product Files
Type Name File Name / Description

Norm references / Approvals

  • Space-saving and flexible
  • For more detailed information, see appendix T8 and data sheets

Application range

  • Allows temperature measurement even in places where non-contact temperature measurement is not possible or reasonable
  • The thermocouple is used to measure temperature as a part of monitoring the manufacturing process, thus the sheath material should be selected with reference to the maximum ambient temperature at its junction.
  • Conductor materials (alloys): 
    Fe/CuNi (LX, JX)
    Conductor alloys are identical to thermocouple alloys
  • NiCr/Ni (K, KX, KCA)
    K and KX version - conductor alloys are identical to thermocouple alloys
    KCA version: compensating alloys (for KCA: Fe/CuNi), not identical to thermocouple alloys
  • PtRh/Pt (RCB, SCB)
    Compensating alloys (for RCB, SCB: Cu/CuNi) are not identical to thermocouple alloys

Norm references / Approvals

  • Colour identity code DIN 43710 Negative conductor and outer sheath:Fe/CuNi: blueNiCr/Ni: greenPtRh/Pt: whitePositive conductor: always redIEC 60 584 Positive conductor and outer sheath:Fe/CuNi: blackNiCr/Ni: greenPtRh/Pt: orangeNegative conductor: always white

Product Make-up

  • Design abbreviations:
    PVC: Polyvinylchloride
    SIL: Silicone rubber
    GL: Glass fibre
    FEP: Fluorinated ethylene propylene
    EGL: E-Glass fibre
    C: Copper braiding screen
    ST: Aluminium foil screen
    S: Steel wire braiding
  • Design, for example PVC-PVC-S-PVC:
    - PVC core insulation
    - PVC inner sheath
    - Steel wire braiding
    - PVC outer sheath
  • Examples shown (top to bottom):
    Fe/CuNi DIN 2 x 1.5 PVC
    NiCr/Ni IEC 2 x 1.5 GL-GL
    PtRh/Pt IEC 2 x 1.5 GL-GL-S
    NiCr/Ni DIN 2 x 1.5 SIL-GL
    NiCr/Ni DIN 2 x 1.5 PVC-PVC
    PtRh/Pt DIN 2 x 1.5 SIL-SIL
    Fe/CuNi IEC 2 x 1.5 SIL-SIL-S
    NiCr/Ni IEC 2 x 1.5 SIL
    PtRh/Pt IEC 2 x 1.5 SIL-GL-S
    Fe/CuNi IEC 2 x 0.22 PVC-PVC-C-PVC
    NiCr/Ni IEC 2 x 1.5 PVC-ST-PVC
    Fe/CuNi DIN 2 x 1.5 PVC-PVC-S-PVC

Temperature range

  • (referring to insulation and sheath material)
    PVC: -5°C to +80°C
    Silicone: -25°C to +180°C
    Glass fibre: -25°C to +200°C
    FEP: -100°C to +205°C
    E-Glass: -25°C to +400°C
 
SKU
LAPP-0152030
Products specifications
Attribute name Attribute value
Number of Conductors 2
Conductor Size 0.5mm