NJ5-18GK-N-150

PPS, Type: 2-wire, Installation: flush, Voltage: DC, cable Silicon , 2 m, IP65

Free shipping on Web orders over $100

$589.00
(Each excl GST)
On Request
Quantity Breaks
1+
5+
25+
$589.00
$589.00
$589.00
SKU: PF-106447 Manufacturer part number: 106447

Technical data of  NJ5-18GK-N-150

General specifications
Switching function Normally closed (NC)
Output type NAMUR
Rated operating distance 5 mm
Installation flush
Assured operating distance 0 ... 4.05 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.3
Reduction factor r304 0.85
Output type 2-wire
Nominal ratings
Nominal voltage 8.2 V (Ri approx. 1 kΩ)
Switching frequency 0 ... 500 Hz
Current consumption
Measuring plate not detected min. 3 mA
Measuring plate detected ≤ 1 mA
Functional safety related parameters
MTTFd 4542 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
NAMUR EN 60947-5-6:2000
IEC 60947-5-6:1999
Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level Ga IECEx PTB 11.0037X
Equipment protection level Gb IECEx PTB 11.0037X
Equipment protection level Da IECEx PTB 11.0037X
Equipment protection level Mb IECEx PTB 11.0037X
ATEX approval
Equipment protection level Ga PTB 00 ATEX 2048 X
Equipment protection level Gb PTB 00 ATEX 2048 X
Equipment protection level Da PTB 00 ATEX 2048 X
EAC conformity TR CU 012/2011
FM approval
Control drawing 116-0165
UL approval
Ordinary Location E87056
Hazardous Location E501628
Control drawing 116-0452
CSA approval cCSAus Listed, General Purpose
CCC approval
Hazardous Location 2020322315002257
NEPSI approval
NEPSI certificate GYJ16.1393X
Ambient conditions
Ambient temperature -40 ... 150 °C (-40 ... 302 °F)
Mechanical specifications
Connection type cable
Housing material PPS
Sensing face PPS
Degree of protection IP65
Cable
Cable diameter 4.8 mm ± 0.2 mm
Bending radius > 10 x cable diameter
Material SIHF
Core cross-section 0.34 mm2
Length 2 m
General information
Use in the hazardous area see instruction manuals
 
SKU
PF-106447
We strive to provide you with the best information we can, considering the images are not to scale and do not represent detailed perspectives of the respected products. If you notice any errors or omissions in this information, please let us know using the contact us tab on this page.
Products specifications
Attribute name Attribute value
Housing Thermoplastic
Connection Type 2m SILICON Cable
Size 18mm
Operating Distance 5mm
Output NAMUR NC
*
*
*
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Product Files

Technical data of  NJ5-18GK-N-150

General specifications
Switching function Normally closed (NC)
Output type NAMUR
Rated operating distance 5 mm
Installation flush
Assured operating distance 0 ... 4.05 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.3
Reduction factor r304 0.85
Output type 2-wire
Nominal ratings
Nominal voltage 8.2 V (Ri approx. 1 kΩ)
Switching frequency 0 ... 500 Hz
Current consumption
Measuring plate not detected min. 3 mA
Measuring plate detected ≤ 1 mA
Functional safety related parameters
MTTFd 4542 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
NAMUR EN 60947-5-6:2000
IEC 60947-5-6:1999
Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level Ga IECEx PTB 11.0037X
Equipment protection level Gb IECEx PTB 11.0037X
Equipment protection level Da IECEx PTB 11.0037X
Equipment protection level Mb IECEx PTB 11.0037X
ATEX approval
Equipment protection level Ga PTB 00 ATEX 2048 X
Equipment protection level Gb PTB 00 ATEX 2048 X
Equipment protection level Da PTB 00 ATEX 2048 X
EAC conformity TR CU 012/2011
FM approval
Control drawing 116-0165
UL approval
Ordinary Location E87056
Hazardous Location E501628
Control drawing 116-0452
CSA approval cCSAus Listed, General Purpose
CCC approval
Hazardous Location 2020322315002257
NEPSI approval
NEPSI certificate GYJ16.1393X
Ambient conditions
Ambient temperature -40 ... 150 °C (-40 ... 302 °F)
Mechanical specifications
Connection type cable
Housing material PPS
Sensing face PPS
Degree of protection IP65
Cable
Cable diameter 4.8 mm ± 0.2 mm
Bending radius > 10 x cable diameter
Material SIHF
Core cross-section 0.34 mm2
Length 2 m
General information
Use in the hazardous area see instruction manuals
 
SKU
PF-106447
Products specifications
Attribute name Attribute value
Housing Thermoplastic
Connection Type 2m SILICON Cable
Size 18mm
Operating Distance 5mm
Output NAMUR NC