You have no items in your shopping cart.

Slot Sensor SJ3,5-S1N

Slot Sensor, Housing: PBT, Output 2-wire, Voltage: DC, Connection flexible leads LiY , 500 mm, P67

Free shipping on Web orders over $100

$238.00
(Each excl GST)
On Request
Quantity Breaks
1+
5+
25+
$238.00
$238.00
$238.00
SKU: PF-273027 Manufacturer part number: 273027

Technical data of  SJ3,5-S1N

General specifications
Switching function Normally open (NO)
Output type NAMUR with safety function
Slot width 3.5 mm
Depth of immersion (lateral) 5 ... 7 typ. 6 mm
Reference target 10 x 7 x 0.3 mm3, Al
Safety Integrity Level (SIL) up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.
Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation.
Output type 2-wire
Nominal ratings
Nominal voltage 8.2 V (Ri approx. 1 kΩ)
Switching frequency 0 ... 2500 Hz
Hysteresis with NAMUR switch amplifier: 0.09 mm (e. g. Pepperl+Fuchs KCD2-SR-Ex1.LB)
with safety switch amplifier 0.05 mm (e. g. Pepperl+Fuchs KFD2-SH-Ex1)
Suitable for 2:1 technology yes , with reverse polarity protection diode
Rate of current rise 2.1 mA / mm
Current consumption
Measuring plate not detected 0.2 ... 1 mA
Measuring plate detected ≥ 3 mA
Functional safety related parameters
Safety Integrity Level (SIL) SIL 3
MTTFd 11850 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
NAMUR EN 60947-5-6:2000
IEC 60947-5-6:1999
Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level Ga IECEx PTB 11.0092X
Equipment protection level Gb IECEx PTB 11.0092X
Equipment protection level Da IECEx PTB 11.0092X
Equipment protection level Mb IECEx PTB 11.0092X
ATEX approval
Equipment protection level Ga PTB 00 ATEX 2049 X
Equipment protection level Gb PTB 00 ATEX 2049 X
Equipment protection level Gc (ic) PF13CERT2895 X
Equipment protection level Da PTB 00 ATEX 2049 X
EAC conformity TR CU 012/2011
FM approval
Control drawing 116-0165
UL approval cULus Listed, General Purpose
Ordinary Location E87056
Hazardous Location E501628
Control drawing 116-0454
CCC approval
Hazardous Location 2020322315002308
NEPSI approval
NEPSI certificate GYJ16.1392X
Ambient conditions
Ambient temperature -25 ... 100 °C (-13 ... 212 °F)
Mechanical specifications
Connection type flexible leads LiY , 500 mm
Core cross-section 0.14 mm2
Housing material PBT
Degree of protection IP67
Note only for non-ferrous metal
Adjustable stop
General information
Use in the hazardous area see instruction manuals
 
SKU
PF-273027
We strive to provide you with the best information we can, considering the images are not to scale and do not represent detailed perspectives of the respected products. If you notice any errors or omissions in this information, please let us know using the contact us tab on this page.
*
*
*
Product Files
Type Name File Name / Description

Technical data of  SJ3,5-S1N

General specifications
Switching function Normally open (NO)
Output type NAMUR with safety function
Slot width 3.5 mm
Depth of immersion (lateral) 5 ... 7 typ. 6 mm
Reference target 10 x 7 x 0.3 mm3, Al
Safety Integrity Level (SIL) up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.
Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation.
Output type 2-wire
Nominal ratings
Nominal voltage 8.2 V (Ri approx. 1 kΩ)
Switching frequency 0 ... 2500 Hz
Hysteresis with NAMUR switch amplifier: 0.09 mm (e. g. Pepperl+Fuchs KCD2-SR-Ex1.LB)
with safety switch amplifier 0.05 mm (e. g. Pepperl+Fuchs KFD2-SH-Ex1)
Suitable for 2:1 technology yes , with reverse polarity protection diode
Rate of current rise 2.1 mA / mm
Current consumption
Measuring plate not detected 0.2 ... 1 mA
Measuring plate detected ≥ 3 mA
Functional safety related parameters
Safety Integrity Level (SIL) SIL 3
MTTFd 11850 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
NAMUR EN 60947-5-6:2000
IEC 60947-5-6:1999
Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level Ga IECEx PTB 11.0092X
Equipment protection level Gb IECEx PTB 11.0092X
Equipment protection level Da IECEx PTB 11.0092X
Equipment protection level Mb IECEx PTB 11.0092X
ATEX approval
Equipment protection level Ga PTB 00 ATEX 2049 X
Equipment protection level Gb PTB 00 ATEX 2049 X
Equipment protection level Gc (ic) PF13CERT2895 X
Equipment protection level Da PTB 00 ATEX 2049 X
EAC conformity TR CU 012/2011
FM approval
Control drawing 116-0165
UL approval cULus Listed, General Purpose
Ordinary Location E87056
Hazardous Location E501628
Control drawing 116-0454
CCC approval
Hazardous Location 2020322315002308
NEPSI approval
NEPSI certificate GYJ16.1392X
Ambient conditions
Ambient temperature -25 ... 100 °C (-13 ... 212 °F)
Mechanical specifications
Connection type flexible leads LiY , 500 mm
Core cross-section 0.14 mm2
Housing material PBT
Degree of protection IP67
Note only for non-ferrous metal
Adjustable stop
General information
Use in the hazardous area see instruction manuals
 
SKU
PF-273027