Temperature Signal Conditioner

JUMPFLEX® Temperature Signal Conditioner for Thermocouples of type J, K

Free shipping on Web orders over $100

$536.00
(Each excl GST)
In Stock
Quantity Breaks
1+
5+
25+
$536.00
$536.00
$536.00
SKU: WAGO-857-811 Manufacturer part number: 857-811 Manufacturer: WAGO

Temperature signal conditioner for thermocouples; Current and voltage output signal; Configuration via software; Supply voltage: 24 VDC; 6 mm module width; light gray

 

WAGO's temperature signal conditioner records signals from thermocouples of type J and K (E, R, N, S, T, B, C) and converts the temperature signal into a standard analog signal.

Features:

  • PC configuration interface
  • For thermocouples of type J and K (E, R, N, S, T, B, C)
  • Cold junction compensation (On/Off)
  • Calibrated measurement range switching
  • Detects a sensor wire break
  • Detects measurement range underflow/overflow
  • Clipping capability for analog signal limitation to output end values
  • 3-way electrical isolation with 2.5 kV test voltage

 

SKU WAGO-857-811
MPN 857-811
GTIN 4045454502751

We strive to provide you with the best information we can, considering the images are not to scale and do not represent detailed perspectives of the respected products. If you notice any errors or omissions in this information, please let us know using the contact us tab on this page.
Products specifications
Attribute name Attribute value
Locally Stocked in NZ Only Show Stocked Items
Locally Stocked in Australia Only Show Stocked Items
*
*
*
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Product Files

Temperature signal conditioner for thermocouples; Current and voltage output signal; Configuration via software; Supply voltage: 24 VDC; 6 mm module width; light gray

 

WAGO's temperature signal conditioner records signals from thermocouples of type J and K (E, R, N, S, T, B, C) and converts the temperature signal into a standard analog signal.

Features:

  • PC configuration interface
  • For thermocouples of type J and K (E, R, N, S, T, B, C)
  • Cold junction compensation (On/Off)
  • Calibrated measurement range switching
  • Detects a sensor wire break
  • Detects measurement range underflow/overflow
  • Clipping capability for analog signal limitation to output end values
  • 3-way electrical isolation with 2.5 kV test voltage

 

SKU WAGO-857-811
MPN 857-811
GTIN 4045454502751