General specifications |
Switching function |
2 x normally closed (NC) |
Output type |
NAMUR |
Rated operating distance |
3 mm |
Installation |
flush mountable |
Assured operating distance |
0 ... 2.4 mm
For assured operating distance sar see Manual Functional Safety. |
Actual operating distance |
2.7 ... 3.3 mm typ. |
Actuating element |
Stainless steel 1.4305 / AISI 303
8.5 mm x 8.5 mm x 0.5 mm |
Reduction factor rAl |
0.4 |
Reduction factor rCu |
0.4 |
Reduction factor r304 |
0.7 |
Reduction factor rSt37 |
1 |
Reduction factor rBrass |
0.5 |
Output type |
2-wire |
Nominal ratings |
Nominal voltage |
8.2 V (Ri approx. 1 kΩ) |
Switching frequency |
0 ... 3 kHz |
Hysteresis |
typ. 5 % |
Reverse polarity protection |
reverse polarity protected |
Short-circuit protection |
yes |
Suitable for 2:1 technology |
yes , Reverse polarity protection diode not required |
Current consumption |
|
|
Measuring plate not detected |
≥ 3 mA |
|
Measuring plate detected |
≤ 1 mA |
Time delay before availability |
≤ 1 ms |
Switching state indicator |
LED, yellow |
Valve status indicator |
LED, yellow |
Functional safety related parameters |
Safety Integrity Level (SIL) |
SIL 2 |
MTTFd |
1730 a |
Mission Time (TM) |
20 a |
Diagnostic Coverage (DC) |
0 % |
Valve circuit |
Voltage |
max. 32 V DC |
Current |
max. 240 mA |
Short-circuit protection |
no |
Reverse polarity protection |
yes, with reversed output LED is out of function, therfore more power for solenoid valve |
Compliance with standards and directives |
Standard conformity |
|
|
NAMUR |
EN 60947-5-6:2000
IEC 60947-5-6:1999 |
|
Electromagnetic compatibility |
NE 21:2007 |
|
Standards |
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012 |
Approvals and certificates |
IECEx approval |
|
|
Equipment protection level Ga |
IECEx TUR 17.0055X |
|
Equipment protection level Gb |
IECEx TUR 17.0055X |
|
Equipment protection level Da |
IECEx TUR 17.0055X |
ATEX approval |
|
|
Equipment protection level Ga |
TÜV 17 ATEX 8125 X |
|
Equipment protection level Gb |
TÜV 17 ATEX 8125 X |
|
Equipment protection level Gc (ic) |
PF13CERT2895 X |
|
Equipment protection level Da |
TÜV 17 ATEX 8125 X |
UL approval |
cULus Listed, General Purpose, Class 2 Power Source |
|
Ordinary Location |
E87056 |
|
Hazardous Location |
E501628 |
|
Control drawing |
116-0455 |
CCC approval |
|
|
Hazardous Location |
2020322315002305 |
NEPSI approval |
|
|
NEPSI certificate |
GYJ18.1172X |
Ambient conditions |
Ambient temperature |
-40 ... 100 °C (-40 ... 212 °F) |
Storage temperature |
-40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications |
Connection type |
screw terminals |
Connection (system side) |
Screw terminals, tightening torque min. 0.5 Nm
Stripped length 7 mm , 1/2" NPT cable gland , usable thread length 13.5 mm , screw-in depth max. 13.5 mm |
Core cross-section (system side) |
rigid: 0.14 ... 2.5 mm2
flexible: 0.14 ... 1.5 mm2
flexible with core-end sleeve: 0.25 ... 1.5 mm2 |
Connection (valve side) |
like connection (system side) |
Core cross-section (valve side) |
like core cross section (system side) |
Housing material |
PC (glass-fiber-reinforced Makrolon) |
Housing base |
powder coated aluminum |
Degree of protection |
IP66 / IP68 / IP69 |
Tightening torque, housing screws |
≤ 2 Nm |
Tightening torque, cable gland |
Refer to NEC (National Electrical Code), hand-tight then wrench tightened (max. 3 turns) |
Note |
LED switch-off |
General information |
Use in the hazardous area |
see instruction manuals |