NCN40-L2-N0-V1

VariKont L ®, PA, Installation: non-flush, Voltage: DC, M12 , 4-pin, IP69K

Free shipping on Web orders over $100

$116.00
(Each excl GST)
On Request
Quantity Breaks
1+
5+
25+
$116.00
$116.00
$116.00
SKU: PF-182706 Manufacturer part number: 182706

Technical data of  NCN40-L2-N0-V1

General specifications
Switching function Normally closed (NC)
Output type NAMUR
Rated operating distance 40 mm
Installation non-flush
Assured operating distance 0 ... 32.4 mm
Actual operating distance 36 ... 44 mm
Reduction factor rAl 0.31
Reduction factor rCu 0.3
Reduction factor r304 0.74
Nominal ratings
Nominal voltage 8.2 V (Ri approx. 1 kΩ)
Switching frequency 0 ... 150 Hz
Hysteresis typ. 5 %
Reverse polarity protection reverse polarity protected
Short-circuit protection yes
Current consumption
Measuring plate not detected ≥ 2.2 mA
Measuring plate detected ≤ 1 mA
Switching state indicator LED, yellow
Functional safety related parameters
MTTFd 1670 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level Ga IECEx PTB 11.0021X
Equipment protection level Gb IECEx PTB 11.0021X
Equipment protection level Da IECEx PTB 11.0021X
Equipment protection level Mb IECEx PTB 11.0021X
ATEX approval
Equipment protection level Ga PTB 00 ATEX 2032 X
Equipment protection level Gb PTB 00 ATEX 2032 X
Equipment protection level Gc (ic) PF13CERT2895 X
Equipment protection level Da PTB 00 ATEX 2032 X
Equipment protection level Dc (tc) PF15CERT3774X
EAC conformity TR CU 012/2011
Protection class II
Rated insulation voltage 253 V
Rated impulse withstand voltage 4000 V
UL approval
Ordinary Location E87056
Hazardous Location E501628
Control drawing 116-0451
CCC approval
Hazardous Location 2020322315002302
NEPSI approval
NEPSI certificate GYJ16.1394X
Marine approval DNVGL TAA00001A5
Ambient conditions
Ambient temperature -25 ... 100 °C (-13 ... 212 °F)
Storage temperature -40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection type Connector plug M12 x 1 , 4-pin
Housing material PA
Sensing face PA
Degree of protection IP69K
Mass 130 g
General information
Use in the hazardous area see instruction manuals
 
SKU
PF-182706
We strive to provide you with the best information we can, considering the images are not to scale and do not represent detailed perspectives of the respected products. If you notice any errors or omissions in this information, please let us know using the contact us tab on this page.
Products specifications
Attribute name Attribute value
Operating Distance 40mm
Output NAMUR NC
*
*
*
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Product Files

Technical data of  NCN40-L2-N0-V1

General specifications
Switching function Normally closed (NC)
Output type NAMUR
Rated operating distance 40 mm
Installation non-flush
Assured operating distance 0 ... 32.4 mm
Actual operating distance 36 ... 44 mm
Reduction factor rAl 0.31
Reduction factor rCu 0.3
Reduction factor r304 0.74
Nominal ratings
Nominal voltage 8.2 V (Ri approx. 1 kΩ)
Switching frequency 0 ... 150 Hz
Hysteresis typ. 5 %
Reverse polarity protection reverse polarity protected
Short-circuit protection yes
Current consumption
Measuring plate not detected ≥ 2.2 mA
Measuring plate detected ≤ 1 mA
Switching state indicator LED, yellow
Functional safety related parameters
MTTFd 1670 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level Ga IECEx PTB 11.0021X
Equipment protection level Gb IECEx PTB 11.0021X
Equipment protection level Da IECEx PTB 11.0021X
Equipment protection level Mb IECEx PTB 11.0021X
ATEX approval
Equipment protection level Ga PTB 00 ATEX 2032 X
Equipment protection level Gb PTB 00 ATEX 2032 X
Equipment protection level Gc (ic) PF13CERT2895 X
Equipment protection level Da PTB 00 ATEX 2032 X
Equipment protection level Dc (tc) PF15CERT3774X
EAC conformity TR CU 012/2011
Protection class II
Rated insulation voltage 253 V
Rated impulse withstand voltage 4000 V
UL approval
Ordinary Location E87056
Hazardous Location E501628
Control drawing 116-0451
CCC approval
Hazardous Location 2020322315002302
NEPSI approval
NEPSI certificate GYJ16.1394X
Marine approval DNVGL TAA00001A5
Ambient conditions
Ambient temperature -25 ... 100 °C (-13 ... 212 °F)
Storage temperature -40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection type Connector plug M12 x 1 , 4-pin
Housing material PA
Sensing face PA
Degree of protection IP69K
Mass 130 g
General information
Use in the hazardous area see instruction manuals
 
SKU
PF-182706
Products specifications
Attribute name Attribute value
Operating Distance 40mm
Output NAMUR NC