NRB20-L3-E2-IO-C-V1

VariKont L ®, GD-ZnAl4Cu1, coated, Type: 3-wire, flush, Voltage: DC, M12 , 4-pin, IP67

Free shipping on Web orders over $100

$315.00
(Each excl GST)
On Request
Quantity Breaks
1+
5+
25+
$315.00
$315.00
$315.00
SKU: PF-306534-0001 Manufacturer part number: 306534-0001

Technical data of  NRB20-L3-E2-IO-C-V1

General specifications
Switching function Normally open/closed (NO/NC) programmable
Output type PNP
Rated operating distance 20 mm (factory setting)
Near operating distance 15 mm (can be activated by software)
Installation flush
Output polarity DC
Assured operating distance 0 ... 16.2 mm
Reduction factor rAl 1
Reduction factor rCu 1
Reduction factor r304 1
Reduction factor rSt37 1
Output type 3-wire
Nominal ratings
Operating voltage 10 ... 30 V DC
Switching frequency 0 ... 440 Hz (switch point mode)
0 ... 10 Hz (window mode, switch point mode with stability alarm)
Hysteresis typ. 3 %
Reverse polarity protection reverse polarity protected
Short-circuit protection pulsing
Voltage drop ≤ 0.5 V
Operating current 0 ... 200 mA
Off-state current 0 ... 0.5 mA typ. 60 µA at 25 °C
No-load supply current ≤ 20 mA
Time delay before availability max. 150 ms
Constant magnetic field 200 mT
Alternating magnetic field 200 mT
Operating voltage indicator LED, green
Status indicator LED, yellow
Functional safety related parameters
MTTFd 701 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Interface
Interface type IO-Link ( via C/Q = pin 4 )
Transfer rate COM 2 (38.4 kBaud)
IO-Link Revision 1.1
Min. cycle time 2.3 ms
Process data width Process data input (control system side): 2 Bit
Process data output (control system side): none
SIO mode support yes
Device ID 0x201003 (2101251)
Compatible master port type A
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
Protection class II
Rated insulation voltage 60 V
Rated impulse withstand voltage 800 V
UL approval cULus Listed, General Purpose
Class 2 power source
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector plug M12 x 1 , 4-pin
Housing material GD-ZnAl4Cu1, coated
mounting flange PA6-GF35
Sensing face PA 6 Grivory GVN-35H
Degree of protection IP67
Mass 180 g
Factory settings
Default setting operating mode = switch point mode with stability alarm
switching function = Normally open (NO)
switching distance = 20 mm
 
SKU
PF-306534-0001
We strive to provide you with the best information we can, considering the images are not to scale and do not represent detailed perspectives of the respected products. If you notice any errors or omissions in this information, please let us know using the contact us tab on this page.
Products specifications
Attribute name Attribute value
Operating Distance 20mm
Output PNP NO
*
*
*
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Product Files

Technical data of  NRB20-L3-E2-IO-C-V1

General specifications
Switching function Normally open/closed (NO/NC) programmable
Output type PNP
Rated operating distance 20 mm (factory setting)
Near operating distance 15 mm (can be activated by software)
Installation flush
Output polarity DC
Assured operating distance 0 ... 16.2 mm
Reduction factor rAl 1
Reduction factor rCu 1
Reduction factor r304 1
Reduction factor rSt37 1
Output type 3-wire
Nominal ratings
Operating voltage 10 ... 30 V DC
Switching frequency 0 ... 440 Hz (switch point mode)
0 ... 10 Hz (window mode, switch point mode with stability alarm)
Hysteresis typ. 3 %
Reverse polarity protection reverse polarity protected
Short-circuit protection pulsing
Voltage drop ≤ 0.5 V
Operating current 0 ... 200 mA
Off-state current 0 ... 0.5 mA typ. 60 µA at 25 °C
No-load supply current ≤ 20 mA
Time delay before availability max. 150 ms
Constant magnetic field 200 mT
Alternating magnetic field 200 mT
Operating voltage indicator LED, green
Status indicator LED, yellow
Functional safety related parameters
MTTFd 701 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Interface
Interface type IO-Link ( via C/Q = pin 4 )
Transfer rate COM 2 (38.4 kBaud)
IO-Link Revision 1.1
Min. cycle time 2.3 ms
Process data width Process data input (control system side): 2 Bit
Process data output (control system side): none
SIO mode support yes
Device ID 0x201003 (2101251)
Compatible master port type A
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
Protection class II
Rated insulation voltage 60 V
Rated impulse withstand voltage 800 V
UL approval cULus Listed, General Purpose
Class 2 power source
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector plug M12 x 1 , 4-pin
Housing material GD-ZnAl4Cu1, coated
mounting flange PA6-GF35
Sensing face PA 6 Grivory GVN-35H
Degree of protection IP67
Mass 180 g
Factory settings
Default setting operating mode = switch point mode with stability alarm
switching function = Normally open (NO)
switching distance = 20 mm
 
SKU
PF-306534-0001
Products specifications
Attribute name Attribute value
Operating Distance 20mm
Output PNP NO